Measurement: 3 Phase 3 Wire or 4 Wire (User Selectable)

Input Current: 0 - 120% of the selected range (1A,5A AC User Selectable)

Input Voltage: 0 - 120% of the selected range (110 or 415 V User Selectable)

Frequency: 40 - 60 Hz

Power Factor: (Lag) 0.5 -1- 0.5 (Lead)

Power: 0-V3*V*I*PF

Continuous: 2 times for Current

Overload: 1.2 times for Voltage

Momentary: 40 times for Current (1 Second)

Overload: 2 times for Voltage (1 Second)

Power Supply: 80 - 300 V AC/DC, 18- 60 V DC

Burden: Less than 5 VA for Auxiliary Supply 0.5 VA for Voltage & Current

Response Time: Less than 500 mSec

Display: 3 Lines of 7 Segment 4 Digits

Keys: 3 Tactile Keys

Comm. Port: RS 232 or RS 485 (Optional)

Isolation: 2 KV, 50 Hz for 1 min between Input, Supply & Communication Port

Insulation: 100 Mohms at 500 V DC for 1 min

Parameter: Vpn, V1, V2, V3, VPP, Vry, Vyb, Vbr, A, A1, A2, A3, W, W1, W2, W3, VAR, VAR1, VAR2, VAR3, VA, VA1, VA2, VA3, Frequency, PF, PF1, PF2, PF3,WH, Import WH, Export WH, VARh, Import VARh, Export VARh, Vah, Demand Parameter(W/VA/A), Run, On Hours,  Interruption  

Category: Transducer

Tags: Transducer

Measurement: 3 Phase 3 Wire or 4 Wire (User Selectable)

Input Current: 0 - 120% of the selected range (1A,5A AC User Selectable)

Input Voltage: 0 - 120% of the selected range (110 or 415 V User Selectable)

Frequency: 40 - 60 Hz

Power Factor: (Lag) 0.5 -1- 0.5 (Lead)

Power: 0-V3*V*I*PF

Continuous: 2 times for Current

Overload: 1.2 times for Voltage

Momentary: 40 times for Current (1 Second)

Overload: 2 times for Voltage (1 Second)

Power Supply: 80 - 300 V AC/DC, 18- 60 V DC

Burden: Less than 5 VA for Auxiliary Supply 0.5 VA for Voltage & Current

Response Time: Less than 500 mSec

Display: 3 Lines of 7 Segment 4 Digits

Keys: 3 Tactile Keys

Comm. Port: RS 232 or RS 485 (Optional)

Isolation: 2 KV, 50 Hz for 1 min between Input, Supply & Communication Port

Insulation: 100 Mohms at 500 V DC for 1 min

Parameter: Vpn, V1, V2, V3, VPP, Vry, Vyb, Vbr, A, A1, A2, A3, W, W1, W2, W3, VAR, VAR1, VAR2, VAR3, VA, VA1, VA2, VA3, Frequency, PF, PF1, PF2, PF3,WH, Import WH, Export WH, VARh, Import VARh, Export VARh, Vah, Demand Parameter(W/VA/A), Run, On Hours,  Interruption  

Specification

Model F3 MFM4
SKU F3 MFM4
Pricing Type Standard
Stock Quantity 0
Status Active
Purchase Flow Standard Checkout

Additional information

Weight 1.000 Kg
Category Count 1